Catalog
Low Voltage UL/CSA Fuses
Class RK1

A2D-R - Class RK1 - Time-Delay
Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace obsolete 250V Class H, K or RK5 fuses already installed in the field.
FEATURES
- Solid-state SmartSpot indicator
- Time-delay for motor starting and transformer inrush currents without nuisance opening
- 300kA interrupting rating, self-certified (UL witnessed)
- Extremely current-limiting for low peak let-thru current
- Easy 2-to-1 selectivity for prevention of nuisance shut downs and "black outs"
- Rejection-style design prevents replacement errors (when used with recommended fuse blocks)
- High-visibility orange label gives instant recognition
- Reduced inventory by taking the place of Class RK5, K, and H fuses
- Metal embossed date and catalog number for easier traceability and lasting identification
- Fiberglass body provides dimensional stability in harsh industrial settings
- High-grade silica filler ensures fast arc quenching
PRODUCT DETAILS
- Volts (VAC) 250 VAC
- Volts (VDC) 250 VDC
- Ampere Range (A) 1/10-600 A
- I.R. AC (kA) 200 kA
- I.R DC (kA) 100 kA
- IR Other (kA) 300kA 250VAC Self Certified (UL Witnessed)
- Class Class RK1
- Speed / Characteristic Time-Delay
- Mounting Clip
-
Connection Terminal Type
Ferrule
Blade -
Body Style
Cylindrical
Rejection - Body Material Polyester
- Materials Contact Tin-plated Copper
-
Standards
UL Listed to Standard 248-12, File E2137
CSA Certified to Standard C22.2, No. 248.12 -
Application
Motors
Safety Switches
Transformers
Disconnects
Control Panels
All General-purpose Circuits - ROHS Compliant Consult Technical Services
- Lead Free Consult Technical Services
- CE conformity Consult Technical Services
-
UL File Card
E2137 JDDZ.E2137
-
CSA File Card
Class: 1422-02 File: 012636_0_000
Catalog-Reference
- A2D1-1/4R - A212704
- A2D1-1/8R - K213219
- A2D1-4/10R - B213717
- A2D1-6/10R - J214230
- A2D1-8/10R - M214739
- A2D1/10R - Q215248
- A2D1/2R - T215757
- A2D100R - P215247
- A2D10R - Z216268
- A2D110R - S215756
- A2D125R - Y216267
- A2D12R - Z216774
- A2D15/100R - M217292
- A2D150R - Y216773
- A2D15R - R217802
- A2D17-1/2R - C218318
- A2D175R - L217291
- A2D1R - Q218836
- A2D2-1/2R - D219354
- A2D2-1/4R - C219882
- A2D2-8/10R - S222564
- A2D2/10R - J223085
- A2D200R - Q217801
- A2D20R - P200872
- A2D225R - B218317
- A2D250R - P218835
- A2D25R - B201412
- A2D2R - P201930
- A2D3-1/2R - M211151
- A2D3-2/10R - E211673
- A2D3/10R - K212184
- A2D300R - C219353
- A2D30R - B212705
- A2D350R - B219881
- A2D35R - L213220
- A2D3R - C213718
- A2D4-1/2R - K214231
- A2D4/10R - N214740
- A2D400R - R222563
- A2D40R - R215249
- A2D450R - H223084
- A2D45R - V215758
- A2D4R - A216269
- A2D5-6/10R - A216775
- A2D500R - N200871
- A2D50R - N217293
- A2D5R - S217803
- A2D6-1/4R - D218319
- A2D6/10R - R218837
- A2D600R - A201411
- A2D60R - E219355
- A2D6R - T222565
- A2D70R - N201929
- A2D75R - L211150
- A2D7R - K223086
- A2D8/10R - Q200873
- A2D80R - D211672
- A2D8R - C201413
- A2D90R - J212183
- A2D9R - Q201931
PERFORMANCE DATA
- A2D(35-60)R Average Time Current Curve (277 KB)
- A2D(15-30)R Average Time Current Curve (278 KB)
- A2D(110-200)R Average Time Current Curve (277 KB)
- A2D(10-12)R Average Time Current Curve (394 KB)
- A2D(35-60)R Peak Let Thru Curve (46 KB)
- A2D(70-100)R Average Time Current Curve (278 KB)
Find what you need fast...
Quick Links
- EP Connect
- Product Selector Tools
- Rapid Prototyping
- R-Tools Heatsink Selector Tool
- Contact Us Form
- Quick quote request
- Sample request
- Keep Me Informed
- Compliance